Arrangement 1: Standard solar system
The controller calculates the temperature difference between collector sensor S1 and store sensor S2. If the difference is larger than or identical to the adjusted switch-on temperature difference (DT O), the solar pump will be activated by relay 1, and the store will be loaded until the switch-off temperature difference (DT F) or the maximum store temperature (S MX) is reached.
Sensors S3 and S4 can optionally be connected for measurement purposes. S3 can optionally be used as the reference sensor for the store emergency shutdown op-tion (OSEM).
Solar Controller
Technical data
Inputs: 4 Pt1000 temperature sensors
Outputs: 2 semiconductor relays
Switching capacity: 1 (1) A 240 V~ (semiconductor relay)
Total switching capacity: 2 A 240 V~
Power supply: 100 … 240 V~ (50 … 60 Hz)
Supply connection: type Y attachment
Standby: 0.38 W
Temperature controls class: I
Mode of operation: type 1.C.Y action
Rated impulse voltage: 2.5 kV
Data interface: RESOL VBus®
VBus® current supply: 35 mA
Protection type: IP 20 / DIN EN 60529
Protection class: II
Ambient temperature: 0 … 40 °C [32 … 104 °F]
Dimensions: 172 x 110 x 49 mm
Functions: function control, operating hours counter, tube collector function, thermostat function, speed control and heat quantity measurement